Attributes { s { time { String _CoordinateAxisType "Time"; Float64 actual_range 1.6540236e+9, 1.665054e+9; Float64 ancillary_variables NaN; String axis "T"; String calendar "proleptic_gregorian"; Float64 comment NaN; String ioos_category "Time"; String long_name "Time"; String sdn_P02_urn "SDN:P02::AYMD"; String sdn_parameter_name "Elapsed time relative to 1970-01-01T00:00:00Z"; String sdn_parameter_uri "https://vocab.nerc.ac.uk/collection/P01/current/ELTMEP01/"; String sdn_parameter_urn "SDN:P01::ELTMEP01"; String sdn_uom_name "seconds"; String sdn_uom_uri "https://vocab.nerc.ac.uk/collection/P06/current/UTBB/"; String sdn_uom_urn "SDN:P06::UTBB"; String standard_name "time"; String time_origin "01-JAN-1970 00:00:00"; String units "seconds since 1970-01-01T00:00:00Z"; } latitude { String _CoordinateAxisType "Lat"; Float32 _FillValue -9999.9; Float32 actual_range 36.84848, 36.84848; String ancillary_variables "POSITION_QC"; String axis "Y"; Float64 colorBarMaximum 90.0; Float64 colorBarMinimum -90.0; Float64 comment NaN; String ioos_category "Location"; String long_name "Latitude of each location"; String sdn_P02_urn "SDN:P02::ALAT"; String sdn_parameter_name "Latitude north"; String sdn_parameter_uri "https://vocab.nerc.ac.uk/collection/P01/current/ALATZZ01/"; String sdn_parameter_urn "SDN:P01::ALATZZ01"; String sdn_uom_name "Degrees north"; String sdn_uom_uri "https://vocab.nerc.ac.uk/collection/P06/current/DEGN/"; String sdn_uom_urn "SDN:P06::DEGN"; String standard_name "latitude"; String units "degrees_north"; } longitude { String _CoordinateAxisType "Lon"; Float32 _FillValue -9999.9; Float32 actual_range -8.927072, -8.927072; String ancillary_variables "POSITION_QC"; String axis "X"; Float64 colorBarMaximum 180.0; Float64 colorBarMinimum -180.0; Float64 comment NaN; String ioos_category "Location"; String long_name "Longitude of each location"; String sdn_P02_urn "SDN:P02::ALAT"; String sdn_parameter_name "Longitude east"; String sdn_parameter_uri "https://vocab.nerc.ac.uk/collection/P01/current/ALONZZ01/"; String sdn_parameter_urn "SDN:P01::ALONZZ01"; String sdn_uom_name "Degrees east"; String sdn_uom_uri "https://vocab.nerc.ac.uk/collection/P06/current/DEGE/"; String sdn_uom_urn "SDN:P06::DEGE"; String standard_name "longitude"; String units "degrees_east"; } POSITION_QC { Float32 _FillValue -9999.9; Float32 actual_range 7.0, 7.0; Float64 colorBarMaximum 10.0; Float64 colorBarMinimum 0.0; String conventions "OceanSITES QC Flags"; String flag_meanings "unknown good_data probably_good_data potentially_correctable_bad_data bad_data nominal_value interpolated_value missing_value"; String flag_values "0, 1, 2, 3, 4, 7, 8, 9"; String ioos_category "Quality"; String long_name "quality flag for LATITUDE and LONGITUDE"; } SVEL { Float64 _FillValue -9999.9; Float64 actual_range 1502.0, 1509.0; String ancillary_variables "SVEL_QC"; Float64 comment NaN; String coordinates "TIME;DEPTH;LATITUDE;LONGITUDE"; String ioos_category "Currents"; String long_name "Sound velocity in sea water"; String sdn_P02_urn "SDN:P02::SVEL"; String sdn_parameter_name "Sound velocity in the water body"; String sdn_parameter_uri "https://vocab.nerc.ac.uk/collection/P01/current/SVELXXXX/"; String sdn_parameter_urn "SDN:P01::SVELXXXX"; String sdn_uom_name "Metres per second"; String sdn_uom_uri "https://vocab.nerc.ac.uk/collection/P06/current/UVAA/"; String sdn_uom_urn "SDN:P06::UVAA"; Int32 sensor_depth 150; String sensor_manufacturer "Teledyne RD Instruments"; String sensor_manufacturer_uri "https://vocab.nerc.ac.uk/collection/L35/current/MAN0010/"; String sensor_manufacturer_urn "SDN:L35::MAN0010"; String sensor_model "Teledyne RDI Sentinel V100 (300 kHz) ADCP"; String sensor_mount "mounted_on_fixed_structure"; String sensor_orientation "upward"; String sensor_reference "https://vocab.nerc.ac.uk/collection/L22/current/TOOL1719/"; String sensor_SeaVoX_L22_code "SDN:L22::TOOL1719"; Int32 sensor_serial_number 318; String sensor_type_name "current profilers"; String sensor_type_uri "https://vocab.nerc.ac.uk/collection/L05/current/115/"; String standard_name "speed_of_sound_in_sea_water"; String units "Metres per second"; } BINNUMBR { Float64 _FillValue -9999.9; Float64 actual_range 0.0, 50.0; Float64 ancillary_variables NaN; Float64 colorBarMaximum 100.0; Float64 colorBarMinimum 0.0; Float64 comment NaN; String coordinates "TIME;DEPTH;LATITUDE;LONGITUDE"; String ioos_category "Statistics"; String long_name "Bin number"; String QC_indicator "good data"; String sdn_P02_urn "SDN:P02::ACYC"; String sdn_parameter_name "Bin number"; String sdn_parameter_uri "https://vocab.nerc.ac.uk/collection/P01/current/BINNUMBR/"; String sdn_parameter_urn "SDN:P01::BINNUMBR"; String sdn_uom_name "Dimensionless"; String sdn_uom_uri "https://vocab.nerc.ac.uk/collection/P06/current/UUUU/"; String sdn_uom_urn "SDN:P06::UUUU"; Int32 sensor_depth 150; String sensor_manufacturer "Teledyne RD Instruments"; String sensor_manufacturer_uri "https://vocab.nerc.ac.uk/collection/L35/current/MAN0010/"; String sensor_manufacturer_urn "SDN:L35::MAN0010"; String sensor_model "Teledyne RDI Sentinel V100 (300 kHz) ADCP"; String sensor_mount "mounted_on_fixed_structure"; String sensor_orientation "upward"; String sensor_reference "https://vocab.nerc.ac.uk/collection/L22/current/TOOL1719/"; String sensor_SeaVoX_L22_code "SDN:L22::TOOL1719"; Int32 sensor_serial_number 318; String sensor_type_name "current profilers"; String sensor_type_uri "https://vocab.nerc.ac.uk/collection/L05/current/115/"; String standard_name "depth_cells"; } HDNG { Float64 _FillValue -9999.9; Float64 actual_range 0.06, 359.98; Float64 ancillary_variables NaN; Float64 comment NaN; String coordinates "TIME;DEPTH;LATITUDE;LONGITUDE"; String ioos_category "Unknown"; String long_name "Heading"; String sdn_P02_urn "SDN:P02::HEAD"; String sdn_parameter_name "Orientation (horizontal relative to true north) of measurement device {heading}"; String sdn_parameter_uri "https://vocab.nerc.ac.uk/collection/P01/current/HEADCM01/"; String sdn_parameter_urn "SDN:P01::HEADCM01"; String sdn_uom_name "Degrees"; String sdn_uom_uri "https://vocab.nerc.ac.uk/collection/P06/current/UAAA/"; String sdn_uom_urn "SDN:P06::UAAA"; Int32 sensor_depth 150; String sensor_manufacturer "Teledyne RD Instruments"; String sensor_manufacturer_uri "https://vocab.nerc.ac.uk/collection/L35/current/MAN0010/"; String sensor_manufacturer_urn "SDN:L35::MAN0010"; String sensor_model "Teledyne RDI Sentinel V100 (300 kHz) ADCP"; String sensor_mount "mounted_on_fixed_structure"; String sensor_orientation "upward"; String sensor_reference "https://vocab.nerc.ac.uk/collection/L22/current/TOOL1719/"; String sensor_SeaVoX_L22_code "SDN:L22::TOOL1719"; Int32 sensor_serial_number 318; String sensor_type_name "current profilers"; String sensor_type_uri "https://vocab.nerc.ac.uk/collection/L05/current/115/"; String standard_name "platform_orientation"; String units "degrees"; } PTCH { Float64 _FillValue -9999.9; Float64 actual_range -1.11, 0.81; Float64 ancillary_variables NaN; Float64 comment NaN; String coordinates "TIME;DEPTH;LATITUDE;LONGITUDE"; String ioos_category "Unknown"; String long_name "Pitch"; String sdn_P02_urn "SDN:P02::HEAD"; String sdn_parameter_name "Orientation (pitch) of measurement platform by inclinometer"; String sdn_parameter_uri "https://vocab.nerc.ac.uk/collection/P01/current/PTCHEI01/"; String sdn_parameter_urn "SDN:P01::PTCHEI01"; String sdn_uom_name "Degrees"; String sdn_uom_uri "https://vocab.nerc.ac.uk/collection/P06/current/UAAA/"; String sdn_uom_urn "SDN:P06::UAAA"; Int32 sensor_depth 150; String sensor_manufacturer "Teledyne RD Instruments"; String sensor_manufacturer_uri "https://vocab.nerc.ac.uk/collection/L35/current/MAN0010/"; String sensor_manufacturer_urn "SDN:L35::MAN0010"; String sensor_model "Teledyne RDI Sentinel V100 (300 kHz) ADCP"; String sensor_mount "mounted_on_fixed_structure"; String sensor_orientation "upward"; String sensor_reference "https://vocab.nerc.ac.uk/collection/L22/current/TOOL1719/"; String sensor_SeaVoX_L22_code "SDN:L22::TOOL1719"; Int32 sensor_serial_number 318; String sensor_type_name "current profilers"; String sensor_type_uri "https://vocab.nerc.ac.uk/collection/L05/current/115/"; String standard_name "platform_pitch"; String units "degrees"; } ROLL { Float64 _FillValue -9999.9; Float64 actual_range -0.64, 1.26; Float64 ancillary_variables NaN; Float64 comment NaN; String coordinates "TIME;DEPTH;LATITUDE;LONGITUDE"; String ioos_category "Unknown"; String long_name "Roll"; String sdn_P02_urn "SDN:P02::HEAD"; String sdn_parameter_name "Orientation (roll angle) of measurement platform by inclinometer"; String sdn_parameter_uri "https://vocab.nerc.ac.uk/collection/P01/current/ROLLEI01/"; String sdn_parameter_urn "SDN:P01::ROLLEI01"; String sdn_uom_name "Degrees"; String sdn_uom_uri "https://vocab.nerc.ac.uk/collection/P06/current/UAAA/"; String sdn_uom_urn "SDN:P06::UAAA"; Int32 sensor_depth 150; String sensor_manufacturer "Teledyne RD Instruments"; String sensor_manufacturer_uri "https://vocab.nerc.ac.uk/collection/L35/current/MAN0010/"; String sensor_manufacturer_urn "SDN:L35::MAN0010"; String sensor_model "Teledyne RDI Sentinel V100 (300 kHz) ADCP"; String sensor_mount "mounted_on_fixed_structure"; String sensor_orientation "upward"; String sensor_reference "https://vocab.nerc.ac.uk/collection/L22/current/TOOL1719/"; String sensor_SeaVoX_L22_code "SDN:L22::TOOL1719"; Int32 sensor_serial_number 318; String sensor_type_name "current profilers"; String sensor_type_uri "https://vocab.nerc.ac.uk/collection/L05/current/115/"; String standard_name "platform_roll"; String units "degrees"; } TEMP { Float64 _FillValue -9999.9; Float64 actual_range 12.77, 15.03; String ancillary_variables "TEMP_QC"; Float64 colorBarMaximum 32.0; Float64 colorBarMinimum 0.0; Float64 comment NaN; String coordinates "TIME;DEPTH;LATITUDE;LONGITUDE"; String ioos_category "Temperature"; String long_name "Sea temperature"; String QC_indicator "good data"; String reference_scale "ITS-90"; String sdn_P02_urn "SDN:P02::TEMP"; String sdn_parameter_name "Temperature of the water body"; String sdn_parameter_uri "https://vocab.nerc.ac.uk/collection/P01/current/TEMPPR01/"; String sdn_parameter_urn "SDN:P01::TEMPPR01"; String sdn_uom_name "Degrees Celsius"; String sdn_uom_uri "https://vocab.nerc.ac.uk/collection/P06/current/UPAA/"; String sdn_uom_urn "SDN:P06::UPAA"; Int32 sensor_depth 150; String sensor_manufacturer "Teledyne RD Instruments"; String sensor_manufacturer_uri "https://vocab.nerc.ac.uk/collection/L35/current/MAN0010/"; String sensor_manufacturer_urn "SDN:L35::MAN0010"; String sensor_model "Teledyne RDI Sentinel V100 (300 kHz) ADCP"; String sensor_mount "mounted_on_fixed_structure"; String sensor_orientation "upward"; String sensor_reference "https://vocab.nerc.ac.uk/collection/L22/current/TOOL1719/"; String sensor_SeaVoX_L22_code "SDN:L22::TOOL1719"; Int32 sensor_serial_number 318; String sensor_type_name "water temperature sensor"; String sensor_type_uri "https://vocab.nerc.ac.uk/collection/L05/current/134/"; String standard_name "sea_water_temperature"; String units "degree_C"; } TEMP_QC { Float64 _FillValue -9999.9; Float64 actual_range 1.0, 1.0; Float64 colorBarMaximum 10.0; Float64 colorBarMinimum 0.0; String conventions "OceanSITES QC Flags"; String flag_meanings "unknown good_data probably_good_data potentially_correctable_bad_data bad_data nominal_value interpolated_value missing_value"; String flag_values "0, 1, 2, 3, 4, 7, 8, 9"; String ioos_category "Quality"; String long_name "quality flag for TEMP"; } HCSP { Float64 _FillValue -9999.9; Float64 actual_range 0.0, 2.355; String ancillary_variables "HCSP_QC"; Float64 colorBarMaximum 0.5; Float64 colorBarMinimum 0.0; Float64 comment NaN; String coordinates "TIME;DEPTH;LATITUDE;LONGITUDE"; String ioos_category "Currents"; String long_name "Horizontal current speed"; Float64 missing_value -9999.0; String QC_indicator "good data"; String sdn_P02_urn "SDN:P02::RFVL"; String sdn_parameter_name "Speed of water current (Eulerian measurement) in the water body"; String sdn_parameter_uri "https://vocab.nerc.ac.uk/collection/P01/current/LCSAZZ01/"; String sdn_parameter_urn "SDN:P01::LCSAZZ01"; String sdn_uom_name "Metres per second"; String sdn_uom_uri "https://vocab.nerc.ac.uk/collection/P06/current/UVAA/"; String sdn_uom_urn "SDN:P06::UVAA"; Int32 sensor_depth 150; String sensor_manufacturer "Teledyne RD Instruments"; String sensor_manufacturer_uri "https://vocab.nerc.ac.uk/collection/L35/current/MAN0010/"; String sensor_manufacturer_urn "SDN:L35::MAN0010"; String sensor_model "Teledyne RDI Sentinel V100 (300 kHz) ADCP"; String sensor_mount "mounted_on_fixed_structure"; String sensor_orientation "upward"; String sensor_reference "https://vocab.nerc.ac.uk/collection/L22/current/TOOL1719/"; String sensor_SeaVoX_L22_code "SDN:L22::TOOL1719"; Int32 sensor_serial_number 318; String sensor_type_name "current profilers"; String sensor_type_uri "https://vocab.nerc.ac.uk/collection/L05/current/115/"; String standard_name "sea_water_speed"; String units "Metres per second"; } HCSP_QC { Float64 _FillValue -9999.9; Float64 actual_range 1.0, 4.0; Float64 colorBarMaximum 10.0; Float64 colorBarMinimum 0.0; String conventions "OceanSITES QC Flags"; String flag_meanings "unknown good_data probably_good_data potentially_correctable_bad_data bad_data nominal_value interpolated_value missing_value"; String flag_values "0, 1, 2, 3, 4, 7, 8, 9"; String ioos_category "Quality"; String long_name "quality flag for HCSP"; } HCDT { Float64 _FillValue -9999.9; Float64 actual_range 0.0, 359.82; String ancillary_variables "HCDT_QC"; Float64 colorBarMaximum 360.0; Float64 colorBarMinimum 0.0; Float64 comment NaN; String coordinates "TIME;DEPTH;LATITUDE;LONGITUDE"; String ioos_category "Currents"; String long_name "Current to direction relative true north"; Float64 missing_value -9999.0; String QC_indicator "good data"; String sdn_P02_urn "SDN:P02::RFVL"; String sdn_parameter_name "Direction (towards) of water current in the water body"; String sdn_parameter_uri "https://vocab.nerc.ac.uk/collection/P01/current/LCDAZZ01/"; String sdn_parameter_urn "SDN:P01::LCDAZZ01"; String sdn_uom_name "Degrees True"; String sdn_uom_uri "https://vocab.nerc.ac.uk/collection/P06/current/UABB/"; String sdn_uom_urn "SDN:P06::UABB"; Int32 sensor_depth 150; String sensor_manufacturer "Teledyne RD Instruments"; String sensor_manufacturer_uri "https://vocab.nerc.ac.uk/collection/L35/current/MAN0010/"; String sensor_manufacturer_urn "SDN:L35::MAN0010"; String sensor_model "Teledyne RDI Sentinel V100 (300 kHz) ADCP"; String sensor_mount "mounted_on_fixed_structure"; String sensor_orientation "upward"; String sensor_reference "https://vocab.nerc.ac.uk/collection/L22/current/TOOL1719/"; String sensor_SeaVoX_L22_code "SDN:L22::TOOL1719"; Int32 sensor_serial_number 318; String sensor_type_name "current profilers"; String sensor_type_uri "https://vocab.nerc.ac.uk/collection/L05/current/115/"; String standard_name "sea_water_velocity_to_direction"; String units "Degrees True"; } HCDT_QC { Float64 _FillValue -9999.9; Float64 actual_range 1.0, 4.0; Float64 colorBarMaximum 10.0; Float64 colorBarMinimum 0.0; String conventions "OceanSITES QC Flags"; String flag_meanings "unknown good_data probably_good_data potentially_correctable_bad_data bad_data nominal_value interpolated_value missing_value"; String flag_values "0, 1, 2, 3, 4, 7, 8, 9"; String ioos_category "Quality"; String long_name "quality flag for HCDT"; } EWCT { Float64 _FillValue -9999.9; Float64 actual_range -2.009, 1.782; String ancillary_variables "EWCT_QC"; Float64 colorBarMaximum 0.5; Float64 colorBarMinimum -0.5; Float64 comment NaN; String coordinates "TIME;DEPTH;LATITUDE;LONGITUDE"; String ioos_category "Currents"; String long_name "West-east current component"; Float64 missing_value -9999.0; String QC_indicator "good data"; String sdn_P02_urn "SDN:P02::RFVL"; String sdn_parameter_name "Eastward velocity of water current in the water body"; String sdn_parameter_uri "https://vocab.nerc.ac.uk/collection/P01/current/LCEWZZ01/"; String sdn_parameter_urn "SDN:P01::LCEWZZ01"; String sdn_uom_name "Metres per second"; String sdn_uom_uri "https://vocab.nerc.ac.uk/collection/P06/current/UVAA/"; String sdn_uom_urn "SDN:P06::UVAA"; Int32 sensor_depth 150; String sensor_manufacturer "Teledyne RD Instruments"; String sensor_manufacturer_uri "https://vocab.nerc.ac.uk/collection/L35/current/MAN0010/"; String sensor_manufacturer_urn "SDN:L35::MAN0010"; String sensor_model "Teledyne RDI Sentinel V100 (300 kHz) ADCP"; String sensor_mount "mounted_on_fixed_structure"; String sensor_orientation "upward"; String sensor_reference "https://vocab.nerc.ac.uk/collection/L22/current/TOOL1719/"; String sensor_SeaVoX_L22_code "SDN:L22::TOOL1719"; Int32 sensor_serial_number 318; String sensor_type_name "current profilers"; String sensor_type_uri "https://vocab.nerc.ac.uk/collection/L05/current/115/"; String standard_name "eastward_sea_water_velocity"; String units "Metres per second"; } EWCT_QC { Float64 _FillValue -9999.9; Float64 actual_range 1.0, 4.0; Float64 colorBarMaximum 10.0; Float64 colorBarMinimum 0.0; String conventions "OceanSITES QC Flags"; String flag_meanings "unknown good_data probably_good_data potentially_correctable_bad_data bad_data nominal_value interpolated_value missing_value"; String flag_values "0, 1, 2, 3, 4, 7, 8, 9"; String ioos_category "Quality"; String long_name "quality flag for EWCT"; } NSCT { Float64 _FillValue -9999.9; Float64 actual_range -1.545, 1.733; String ancillary_variables "NSCT_QC"; Float64 colorBarMaximum 0.5; Float64 colorBarMinimum -0.5; Float64 comment NaN; String coordinates "TIME;DEPTH;LATITUDE;LONGITUDE"; String ioos_category "Currents"; String long_name "South-north current component"; Float64 missing_value -9999.0; String QC_indicator "good data"; String sdn_P02_urn "SDN:P02::RFVL"; String sdn_parameter_name "Northward velocity of water current in the water body"; String sdn_parameter_uri "https://vocab.nerc.ac.uk/collection/P01/current/LCNSZZ01/"; String sdn_parameter_urn "SDN:P01::LCNSZZ01"; String sdn_uom_name "Metres per second"; String sdn_uom_uri "https://vocab.nerc.ac.uk/collection/P06/current/UVAA/"; String sdn_uom_urn "SDN:P06::UVAA"; Int32 sensor_depth 150; String sensor_manufacturer "Teledyne RD Instruments"; String sensor_manufacturer_uri "https://vocab.nerc.ac.uk/collection/L35/current/MAN0010/"; String sensor_manufacturer_urn "SDN:L35::MAN0010"; String sensor_model "Teledyne RDI Sentinel V100 (300 kHz) ADCP"; String sensor_mount "mounted_on_fixed_structure"; String sensor_orientation "upward"; String sensor_reference "https://vocab.nerc.ac.uk/collection/L22/current/TOOL1719/"; String sensor_SeaVoX_L22_code "SDN:L22::TOOL1719"; Int32 sensor_serial_number 318; String sensor_type_name "current profilers"; String sensor_type_uri "https://vocab.nerc.ac.uk/collection/L05/current/115/"; String standard_name "northward_sea_water_velocity"; String units "Metres per second"; } NSCT_QC { Float64 _FillValue -9999.9; Float64 actual_range 1.0, 4.0; Float64 colorBarMaximum 10.0; Float64 colorBarMinimum 0.0; String conventions "OceanSITES QC Flags"; String flag_meanings "unknown good_data probably_good_data potentially_correctable_bad_data bad_data nominal_value interpolated_value missing_value"; String flag_values "0, 1, 2, 3, 4, 7, 8, 9"; String ioos_category "Quality"; String long_name "quality flag for NSCT"; } VSP { Float64 _FillValue -9999.9; Float64 actual_range -0.86, 0.589; String ancillary_variables "VCSP_QC"; Float64 colorBarMaximum 0.5; Float64 colorBarMinimum -0.5; Float64 comment NaN; String coordinates "TIME;DEPTH;LATITUDE;LONGITUDE"; String ioos_category "Currents"; String long_name "Bottom-up current component"; Float64 missing_value -9999.0; String QC_indicator "good data"; String sdn_P02_urn "SDN:P02::LRZA"; String sdn_parameter_name "Upward velocity of water current in the water body"; String sdn_parameter_uri "https://vocab.nerc.ac.uk/collection/P01/current/LRZAZZZZ/"; String sdn_parameter_urn "SDN:P01::LRZAZZZZ"; String sdn_uom_name "Metres per second"; String sdn_uom_uri "https://vocab.nerc.ac.uk/collection/P06/current/UVAA/"; String sdn_uom_urn "SDN:P06::UVAA"; Int32 sensor_depth 150; String sensor_manufacturer "Teledyne RD Instruments"; String sensor_manufacturer_uri "https://vocab.nerc.ac.uk/collection/L35/current/MAN0010/"; String sensor_manufacturer_urn "SDN:L35::MAN0010"; String sensor_model "Teledyne RDI Sentinel V100 (300 kHz) ADCP"; String sensor_mount "mounted_on_fixed_structure"; String sensor_orientation "upward"; String sensor_reference "https://vocab.nerc.ac.uk/collection/L22/current/TOOL1719/"; String sensor_SeaVoX_L22_code "SDN:L22::TOOL1719"; Int32 sensor_serial_number 318; String sensor_type_name "current profilers"; String sensor_type_uri "https://vocab.nerc.ac.uk/collection/L05/current/115/"; String standard_name "upward_sea_water_velocity"; String units "Metres per second"; } VSP_QC { Float64 _FillValue -9999.9; Float64 actual_range 1.0, 4.0; Float64 colorBarMaximum 10.0; Float64 colorBarMinimum 0.0; String conventions "OceanSITES QC Flags"; String flag_meanings "unknown good_data probably_good_data potentially_correctable_bad_data bad_data nominal_value interpolated_value missing_value"; String flag_values "0, 1, 2, 3, 4, 7, 8, 9"; String ioos_category "Quality"; String long_name "quality flag for VSP"; } LERR { Float64 _FillValue -9999.9; Float64 actual_range -1.433, 0.755; Float64 ancillary_variables NaN; Float64 colorBarMaximum 50.0; Float64 colorBarMinimum 0.0; Float64 comment NaN; String coordinates "TIME;DEPTH;LATITUDE;LONGITUDE"; String ioos_category "Statistics"; String long_name "Velocity error"; Float64 missing_value -9999.0; String sdn_P02_urn "SDN:P02::TMES"; String sdn_parameter_name "Error velocity of water current in the water body by moored acoustic doppler current profiler (ADCP)"; String sdn_parameter_uri "https://vocab.nerc.ac.uk/collection/P01/current/LERRAP01/"; String sdn_parameter_urn "SDN:P01::LERRAP01"; String sdn_uom_name "Metres per second"; String sdn_uom_uri "https://vocab.nerc.ac.uk/collection/P06/current/UVAA/"; String sdn_uom_urn "SDN:P06::UVAA"; Int32 sensor_depth 150; String sensor_manufacturer "Teledyne RD Instruments"; String sensor_manufacturer_uri "https://vocab.nerc.ac.uk/collection/L35/current/MAN0010/"; String sensor_manufacturer_urn "SDN:L35::MAN0010"; String sensor_model "Teledyne RDI Sentinel V100 (300 kHz) ADCP"; String sensor_mount "mounted_on_fixed_structure"; String sensor_orientation "upward"; String sensor_reference "https://vocab.nerc.ac.uk/collection/L22/current/TOOL1719/"; String sensor_SeaVoX_L22_code "SDN:L22::TOOL1719"; Int32 sensor_serial_number 318; String sensor_type_name "current profilers"; String sensor_type_uri "https://vocab.nerc.ac.uk/collection/L05/current/115/"; String standard_name "indicative_error_from_multibeam_acoustic_doppler_velocity_profiler_in_sea_water"; String units "Metres per second"; } TNIH01 { Float64 _FillValue -9999.9; Float64 actual_range 37.0, 157.0; Float64 ancillary_variables NaN; Float64 colorBarMaximum 100.0; Float64 colorBarMinimum 0.0; Float64 comment NaN; String coordinates "TIME;DEPTH;LATITUDE;LONGITUDE"; String ioos_category "Statistics"; String long_name "Echo intensity beam 1"; String QC_indicator "good data"; String sdn_P02_urn "SDN:P02::TMES"; String sdn_parameter_name "Echo intensity of acoustic signal returns from the water body by moored acoustic doppler current profiler (ADCP) beam 1"; String sdn_parameter_uri "https://vocab.nerc.ac.uk/collection/P01/current/TNIHCE01/"; String sdn_parameter_urn "SDN:P01::TNIHCE01"; String sdn_uom_name "Counts"; String sdn_uom_uri "https://vocab.nerc.ac.uk/collection/P06/current/UUUU/"; String sdn_uom_urn "SDN:P06::UCNT"; Int32 sensor_depth 150; String sensor_manufacturer "Teledyne RD Instruments"; String sensor_manufacturer_uri "https://vocab.nerc.ac.uk/collection/L35/current/MAN0010/"; String sensor_manufacturer_urn "SDN:L35::MAN0010"; String sensor_model "Teledyne RDI Sentinel V100 (300 kHz) ADCP"; String sensor_mount "mounted_on_fixed_structure"; String sensor_orientation "upward"; String sensor_reference "https://vocab.nerc.ac.uk/collection/L22/current/TOOL1719/"; String sensor_SeaVoX_L22_code "SDN:L22::TOOL1719"; Int32 sensor_serial_number 318; String sensor_type_name "current profilers"; String sensor_type_uri "https://vocab.nerc.ac.uk/collection/L05/current/115/"; String standard_name "signal_intensity_from_multibeam_acoustic_doppler_velocity_sensor_in_sea_water"; String units "count"; } TNIH02 { Float64 _FillValue -9999.9; Float64 actual_range 39.0, 159.0; Float64 ancillary_variables NaN; Float64 colorBarMaximum 100.0; Float64 colorBarMinimum 0.0; Float64 comment NaN; String coordinates "TIME;DEPTH;LATITUDE;LONGITUDE"; String ioos_category "Statistics"; String long_name "Echo intensity beam 2"; String QC_indicator "good data"; String sdn_P02_urn "SDN:P02::TMES"; String sdn_parameter_name "Echo intensity of acoustic signal returns from the water body by moored acoustic doppler current profiler (ADCP) beam 2"; String sdn_parameter_uri "https://vocab.nerc.ac.uk/collection/P01/current/TNIHCE02/"; String sdn_parameter_urn "SDN:P01::TNIHCE02"; String sdn_uom_name "Counts"; String sdn_uom_uri "https://vocab.nerc.ac.uk/collection/P06/current/UUUU/"; String sdn_uom_urn "SDN:P06::UCNT"; Int32 sensor_depth 150; String sensor_manufacturer "Teledyne RD Instruments"; String sensor_manufacturer_uri "https://vocab.nerc.ac.uk/collection/L35/current/MAN0010/"; String sensor_manufacturer_urn "SDN:L35::MAN0010"; String sensor_model "Teledyne RDI Sentinel V100 (300 kHz) ADCP"; String sensor_mount "mounted_on_fixed_structure"; String sensor_orientation "upward"; String sensor_reference "https://vocab.nerc.ac.uk/collection/L22/current/TOOL1719/"; String sensor_SeaVoX_L22_code "SDN:L22::TOOL1719"; Int32 sensor_serial_number 318; String sensor_type_name "current profilers"; String sensor_type_uri "https://vocab.nerc.ac.uk/collection/L05/current/115/"; String standard_name "signal_intensity_from_multibeam_acoustic_doppler_velocity_sensor_in_sea_water"; String units "count"; } TNIH03 { Float64 _FillValue -9999.9; Float64 actual_range 38.0, 168.0; Float64 ancillary_variables NaN; Float64 colorBarMaximum 100.0; Float64 colorBarMinimum 0.0; Float64 comment NaN; String coordinates "TIME;DEPTH;LATITUDE;LONGITUDE"; String ioos_category "Statistics"; String long_name "Echo intensity beam 3"; String QC_indicator "good data"; String sdn_P02_urn "SDN:P02::TMES"; String sdn_parameter_name "Echo intensity of acoustic signal returns from the water body by moored acoustic doppler current profiler (ADCP) beam 3"; String sdn_parameter_uri "https://vocab.nerc.ac.uk/collection/P01/current/TNIHCE03/"; String sdn_parameter_urn "SDN:P01::TNIHCE03"; String sdn_uom_name "Counts"; String sdn_uom_uri "https://vocab.nerc.ac.uk/collection/P06/current/UUUU/"; String sdn_uom_urn "SDN:P06::UCNT"; Int32 sensor_depth 150; String sensor_manufacturer "Teledyne RD Instruments"; String sensor_manufacturer_uri "https://vocab.nerc.ac.uk/collection/L35/current/MAN0010/"; String sensor_manufacturer_urn "SDN:L35::MAN0010"; String sensor_model "Teledyne RDI Sentinel V100 (300 kHz) ADCP"; String sensor_mount "mounted_on_fixed_structure"; String sensor_orientation "upward"; String sensor_reference "https://vocab.nerc.ac.uk/collection/L22/current/TOOL1719/"; String sensor_SeaVoX_L22_code "SDN:L22::TOOL1719"; Int32 sensor_serial_number 318; String sensor_type_name "current profilers"; String sensor_type_uri "https://vocab.nerc.ac.uk/collection/L05/current/115/"; String standard_name "signal_intensity_from_multibeam_acoustic_doppler_velocity_sensor_in_sea_water"; String units "count"; } TNIH04 { Float64 _FillValue -9999.9; Float64 actual_range 37.0, 167.0; Float64 ancillary_variables NaN; Float64 colorBarMaximum 100.0; Float64 colorBarMinimum 0.0; Float64 comment NaN; String coordinates "TIME;DEPTH;LATITUDE;LONGITUDE"; String ioos_category "Statistics"; String long_name "Echo intensity beam 4"; String QC_indicator "good data"; String sdn_P02_urn "SDN:P02::TMES"; String sdn_parameter_name "Echo intensity of acoustic signal returns from the water body by moored acoustic doppler current profiler (ADCP) beam 4"; String sdn_parameter_uri "https://vocab.nerc.ac.uk/collection/P01/current/TNIHCE04/"; String sdn_parameter_urn "SDN:P01::TNIHCE04"; String sdn_uom_name "Counts"; String sdn_uom_uri "https://vocab.nerc.ac.uk/collection/P06/current/UUUU/"; String sdn_uom_urn "SDN:P06::UCNT"; Int32 sensor_depth 150; String sensor_manufacturer "Teledyne RD Instruments"; String sensor_manufacturer_uri "https://vocab.nerc.ac.uk/collection/L35/current/MAN0010/"; String sensor_manufacturer_urn "SDN:L35::MAN0010"; String sensor_model "Teledyne RDI Sentinel V100 (300 kHz) ADCP"; String sensor_mount "mounted_on_fixed_structure"; String sensor_orientation "upward"; String sensor_reference "https://vocab.nerc.ac.uk/collection/L22/current/TOOL1719/"; String sensor_SeaVoX_L22_code "SDN:L22::TOOL1719"; Int32 sensor_serial_number 318; String sensor_type_name "current profilers"; String sensor_type_uri "https://vocab.nerc.ac.uk/collection/L05/current/115/"; String standard_name "signal_intensity_from_multibeam_acoustic_doppler_velocity_sensor_in_sea_water"; String units "count"; } PCDG_3_beam_solution { Float64 _FillValue -9999.9; Float64 actual_range 0.0, 100.0; Float64 ancillary_variables NaN; Float64 colorBarMaximum 100.0; Float64 colorBarMinimum 0.0; Float64 comment NaN; String coordinates "TIME;DEPTH;LATITUDE;LONGITUDE"; String ioos_category "Unknown"; String long_name "Percent good 3 beam solution"; String sdn_P02_urn "SDN:P02::TMES"; String sdn_parameter_name "Acceptable proportion of acoustic signal returns {percent good} from the water body by acoustic doppler current profiler (ADCP)"; String sdn_parameter_uri "https://vocab.nerc.ac.uk/collection/P01/current/PCGDAP01/"; String sdn_parameter_urn "SDN:P01::PCGDAP01"; String sdn_uom_name "Percent"; String sdn_uom_uri "https://vocab.nerc.ac.uk/collection/P06/current/UPCT/"; String sdn_uom_urn "SDN:P06::UPCT"; Int32 sensor_depth 150; String sensor_manufacturer "Teledyne RD Instruments"; String sensor_manufacturer_uri "https://vocab.nerc.ac.uk/collection/L35/current/MAN0010/"; String sensor_manufacturer_urn "SDN:L35::MAN0010"; String sensor_model "Teledyne RDI Sentinel V100 (300 kHz) ADCP"; String sensor_mount "mounted_on_fixed_structure"; String sensor_orientation "upward"; String sensor_reference "https://vocab.nerc.ac.uk/collection/L22/current/TOOL1719/"; String sensor_SeaVoX_L22_code "SDN:L22::TOOL1719"; Int32 sensor_serial_number 318; String sensor_type_name "current profilers"; String sensor_type_uri "https://vocab.nerc.ac.uk/collection/L05/current/115/"; String standard_name "proportion_of_acceptable_signal_returns_from_acoustic_instrument_in_sea_water"; String units "Percent"; } PCGD_Rej { Float64 _FillValue -9999.9; Float64 actual_range 0.0, 13.0; Float64 ancillary_variables NaN; Float64 colorBarMaximum 5.0; Float64 colorBarMinimum 0.0; Float64 comment NaN; String coordinates "TIME;DEPTH;LATITUDE;LONGITUDE"; String ioos_category "Statistics"; String long_name "Percentage of error velocity rejections"; String sdn_P02_urn "SDN:P02::TMES"; String sdn_parameter_name "Acceptable proportion of acoustic signal returns {percent good} from the water body by acoustic doppler current profiler (ADCP)"; String sdn_parameter_uri "https://vocab.nerc.ac.uk/collection/P01/current/PCGDAP01/"; String sdn_parameter_urn "SDN:P01::PCGDAP01"; String sdn_uom_name "Percent"; String sdn_uom_uri "https://vocab.nerc.ac.uk/collection/P06/current/UPCT/"; String sdn_uom_urn "SDN:P06::UPCT"; Int32 sensor_depth 150; String sensor_manufacturer "Teledyne RD Instruments"; String sensor_manufacturer_uri "https://vocab.nerc.ac.uk/collection/L35/current/MAN0010/"; String sensor_manufacturer_urn "SDN:L35::MAN0010"; String sensor_model "Teledyne RDI Sentinel V100 (300 kHz) ADCP"; String sensor_mount "mounted_on_fixed_structure"; String sensor_orientation "upward"; String sensor_reference "https://vocab.nerc.ac.uk/collection/L22/current/TOOL1719/"; String sensor_SeaVoX_L22_code "SDN:L22::TOOL1719"; Int32 sensor_serial_number 318; String sensor_type_name "current profilers"; String sensor_type_uri "https://vocab.nerc.ac.uk/collection/L05/current/115/"; String standard_name "proportion_of_acceptable_signal_returns_from_acoustic_instrument_in_sea_water"; String units "Percent"; } PCGD_bad { Float64 _FillValue -9999.9; Float64 actual_range 0.0, 100.0; Float64 ancillary_variables NaN; Float64 colorBarMaximum 100.0; Float64 colorBarMinimum 0.0; Float64 comment NaN; String coordinates "TIME;DEPTH;LATITUDE;LONGITUDE"; String ioos_category "Unknown"; String long_name "Percentage of more than two beams bad"; String sdn_P02_urn "SDN:P02::TMES"; String sdn_parameter_name "Acceptable proportion of acoustic signal returns {percent good} from the water body by acoustic doppler current profiler (ADCP)"; String sdn_parameter_uri "https://vocab.nerc.ac.uk/collection/P01/current/PCGDAP01/"; String sdn_parameter_urn "SDN:P01::PCGDAP01"; String sdn_uom_name "Percent"; String sdn_uom_uri "https://vocab.nerc.ac.uk/collection/P06/current/UPCT/"; String sdn_uom_urn "SDN:P06::UPCT"; Int32 sensor_depth 150; String sensor_manufacturer "Teledyne RD Instruments"; String sensor_manufacturer_uri "https://vocab.nerc.ac.uk/collection/L35/current/MAN0010/"; String sensor_manufacturer_urn "SDN:L35::MAN0010"; String sensor_model "Teledyne RDI Sentinel V100 (300 kHz) ADCP"; String sensor_mount "mounted_on_fixed_structure"; String sensor_orientation "upward"; String sensor_reference "https://vocab.nerc.ac.uk/collection/L22/current/TOOL1719/"; String sensor_SeaVoX_L22_code "SDN:L22::TOOL1719"; Int32 sensor_serial_number 318; String sensor_type_name "current profilers"; String sensor_type_uri "https://vocab.nerc.ac.uk/collection/L05/current/115/"; String standard_name "proportion_of_acceptable_signal_returns_from_acoustic_instrument_in_sea_water"; String units "Percent"; } PCGD_4_beam_solution { Float64 _FillValue -9999.9; Float64 actual_range 0.0, 100.0; Float64 ancillary_variables NaN; Float64 colorBarMaximum 100.0; Float64 colorBarMinimum 0.0; Float64 comment NaN; String coordinates "TIME;DEPTH;LATITUDE;LONGITUDE"; String ioos_category "Unknown"; String long_name "percentage of 4 beam solution"; String sdn_P02_urn "SDN:P02::TMES"; String sdn_parameter_name "Acceptable proportion of acoustic signal returns {percent good} from the water body by acoustic doppler current profiler (ADCP)"; String sdn_parameter_uri "https://vocab.nerc.ac.uk/collection/P01/current/PCGDAP01/"; String sdn_parameter_urn "SDN:P01::PCGDAP01"; String sdn_uom_name "Percent"; String sdn_uom_uri "https://vocab.nerc.ac.uk/collection/P06/current/UPCT/"; String sdn_uom_urn "SDN:P06::UPCT"; Int32 sensor_depth 150; String sensor_manufacturer "Teledyne RD Instruments"; String sensor_manufacturer_uri "https://vocab.nerc.ac.uk/collection/L35/current/MAN0010/"; String sensor_manufacturer_urn "SDN:L35::MAN0010"; String sensor_model "Teledyne RDI Sentinel V100 (300 kHz) ADCP"; String sensor_mount "mounted_on_fixed_structure"; String sensor_orientation "upward"; String sensor_reference "https://vocab.nerc.ac.uk/collection/L22/current/TOOL1719/"; String sensor_SeaVoX_L22_code "SDN:L22::TOOL1719"; Int32 sensor_serial_number 318; String sensor_type_name "current profilers"; String sensor_type_uri "https://vocab.nerc.ac.uk/collection/L05/current/115/"; String standard_name "proportion_of_acceptable_signal_returns_from_acoustic_instrument_in_sea_water"; String units "Percent"; } CMAG01 { Float64 _FillValue -9999.9; Float64 actual_range 7.0, 131.0; String ancillary_variables "CMAG_QC"; Float64 comment NaN; String coordinates "TIME;DEPTH;LATITUDE;LONGITUDE"; String ioos_category "Unknown"; String long_name "Correlation beam 1"; Float64 missing_value -9999.0; String QC_indicator "good data"; String sdn_P02_urn "SDN:P02::TMES"; String sdn_parameter_name "Correlation magnitude of acoustic signal returns from the water body by moored acoustic doppler current profiler (ADCP) beam 1"; String sdn_parameter_uri "https://vocab.nerc.ac.uk/collection/P01/current/CMAGZZ01/"; String sdn_parameter_urn "SDN:P01::CMAGZZ01"; String sdn_uom_name "Dimensionless"; String sdn_uom_uri "https://vocab.nerc.ac.uk/collection/P06/current/UUUU/"; String sdn_uom_urn "SDN:P06::UUUU"; Int32 sensor_depth 150; String sensor_manufacturer "Teledyne RD Instruments"; String sensor_manufacturer_uri "https://vocab.nerc.ac.uk/collection/L35/current/MAN0010/"; String sensor_manufacturer_urn "SDN:L35::MAN0010"; String sensor_model "Teledyne RDI Sentinel V100 (300 kHz) ADCP"; String sensor_mount "mounted_on_fixed_structure"; String sensor_orientation "upward"; String sensor_reference "https://vocab.nerc.ac.uk/collection/L22/current/TOOL1719/"; String sensor_SeaVoX_L22_code "SDN:L22::TOOL1719"; Int32 sensor_serial_number 318; String sensor_type_name "current profilers"; String sensor_type_uri "https://vocab.nerc.ac.uk/collection/L05/current/115/"; String standard_name "correlation_magnitude"; } CMAG02 { Float64 _FillValue -9999.9; Float64 actual_range 7.0, 132.0; Float64 ancillary_variables NaN; Float64 comment NaN; String coordinates "TIME;DEPTH;LATITUDE;LONGITUDE"; String ioos_category "Unknown"; String long_name "Correlation beam 2"; Float64 missing_value -9999.0; String QC_indicator "good data"; String sdn_P02_urn "SDN:P02::TMES"; String sdn_parameter_name "Correlation magnitude of acoustic signal returns from the water body by moored acoustic doppler current profiler (ADCP) beam 2"; String sdn_parameter_uri "https://vocab.nerc.ac.uk/collection/P01/current/CMAGZZ02/"; String sdn_parameter_urn "SDN:P01::CMAGZZ02"; String sdn_uom_name "Dimensionless"; String sdn_uom_uri "https://vocab.nerc.ac.uk/collection/P06/current/UUUU/"; String sdn_uom_urn "SDN:P06::UUUU"; Int32 sensor_depth 150; String sensor_manufacturer "Teledyne RD Instruments"; String sensor_manufacturer_uri "https://vocab.nerc.ac.uk/collection/L35/current/MAN0010/"; String sensor_manufacturer_urn "SDN:L35::MAN0010"; String sensor_model "Teledyne RDI Sentinel V100 (300 kHz) ADCP"; String sensor_mount "mounted_on_fixed_structure"; String sensor_orientation "upward"; String sensor_reference "https://vocab.nerc.ac.uk/collection/L22/current/TOOL1719/"; String sensor_SeaVoX_L22_code "SDN:L22::TOOL1719"; Int32 sensor_serial_number 318; String sensor_type_name "current profilers"; String sensor_type_uri "https://vocab.nerc.ac.uk/collection/L05/current/115/"; String standard_name "correlation_magnitude"; } CMAG03 { Float64 _FillValue -9999.9; Float64 actual_range 7.0, 136.0; Float64 ancillary_variables NaN; Float64 comment NaN; String coordinates "TIME;DEPTH;LATITUDE;LONGITUDE"; String ioos_category "Unknown"; String long_name "Correlation beam 3"; Float64 missing_value -9999.0; String QC_indicator "good data"; String sdn_P02_urn "SDN:P02::TMES"; String sdn_parameter_name "Correlation magnitude of acoustic signal returns from the water body by moored acoustic doppler current profiler (ADCP) beam 3"; String sdn_parameter_uri "https://vocab.nerc.ac.uk/collection/P01/current/CMAGZZ03/"; String sdn_parameter_urn "SDN:P01::CMAGZZ03"; String sdn_uom_name "Dimensionless"; String sdn_uom_uri "https://vocab.nerc.ac.uk/collection/P06/current/UUUU/"; String sdn_uom_urn "SDN:P06::UUUU"; Int32 sensor_depth 150; String sensor_manufacturer "Teledyne RD Instruments"; String sensor_manufacturer_uri "https://vocab.nerc.ac.uk/collection/L35/current/MAN0010/"; String sensor_manufacturer_urn "SDN:L35::MAN0010"; String sensor_model "Teledyne RDI Sentinel V100 (300 kHz) ADCP"; String sensor_mount "mounted_on_fixed_structure"; String sensor_orientation "upward"; String sensor_reference "https://vocab.nerc.ac.uk/collection/L22/current/TOOL1719/"; String sensor_SeaVoX_L22_code "SDN:L22::TOOL1719"; Int32 sensor_serial_number 24601; String sensor_type_name "current profilers"; String sensor_type_uri "https://vocab.nerc.ac.uk/collection/L05/current/115/"; String standard_name "correlation_magnitude"; } CMAG04 { Float64 _FillValue -9999.9; Float64 actual_range 7.0, 134.0; Float64 ancillary_variables NaN; Float64 comment NaN; String coordinates "TIME;DEPTH;LATITUDE;LONGITUDE"; String ioos_category "Unknown"; String long_name "Correlation beam 4"; Float64 missing_value -9999.0; String QC_indicator "good data"; String sdn_P02_urn "SDN:P02::TMES"; String sdn_parameter_name "Correlation magnitude of acoustic signal returns from the water body by moored acoustic doppler current profiler (ADCP) beam 4"; String sdn_parameter_uri "https://vocab.nerc.ac.uk/collection/P01/current/CMAGZZ04/"; String sdn_parameter_urn "SDN:P01::CMAGZZ04"; String sdn_uom_name "Dimensionless"; String sdn_uom_uri "https://vocab.nerc.ac.uk/collection/P06/current/UUUU/"; String sdn_uom_urn "SDN:P06::UUUU"; Int32 sensor_depth 150; String sensor_manufacturer "Teledyne RD Instruments"; String sensor_manufacturer_uri "https://vocab.nerc.ac.uk/collection/L35/current/MAN0010/"; String sensor_manufacturer_urn "SDN:L35::MAN0010"; String sensor_model "Teledyne RDI Sentinel V100 (300 kHz) ADCP"; String sensor_mount "mounted_on_fixed_structure"; String sensor_orientation "upward"; String sensor_reference "https://vocab.nerc.ac.uk/collection/L22/current/TOOL1719/"; String sensor_SeaVoX_L22_code "SDN:L22::TOOL1719"; Int32 sensor_serial_number 318; String sensor_type_name "current profilers"; String sensor_type_uri "https://vocab.nerc.ac.uk/collection/L05/current/115/"; String standard_name "correlation_magnitude"; } } NC_GLOBAL { String cdm_data_type "Point"; String Conventions "OceanSITES v1.4;SeaDataNet_1.0;COARDS; CF-1.6; CMEMS INSTAC v3.2, ACDD-1.3, NCCSV-1.1"; String creator_name "EMSO, CCMAR, IPMA"; String creator_url "https://www.emso.eu/"; String data_mode "D"; String data_type "OceanSITES time-series data"; String date_created "2022-10-14T17:00:00Z"; String doi "https://doi.org/10.17882/94769"; Float64 Easternmost_Easting -8.927072; String emso_facility "Iberian Margin"; String featureType "Point"; Float64 format_version 1.4; Float64 geospatial_lat_max 36.84848; Float64 geospatial_lat_min 36.84848; String geospatial_lat_units "degrees_north"; Float64 geospatial_lon_max -8.927072; Float64 geospatial_lon_min -8.927072; String geospatial_lon_units "degrees_east"; Int32 geospatial_vertical_max 152; Int32 geospatial_vertical_min 148; String history "Subsurface upward facing ADCP 2025-01-15T11:34:43Z (local files) 2025-01-15T11:34:43Z https://erddap.emso.eu/erddap/tabledap/IBMA-CSV_ADCP_d02_20220531_to_20221006_v002.das"; String infoUrl "https://www.ccmar.ualg.pt/"; String insitution_ror_uri "https://ror.org/00me37y22"; String institution "Algarve Centre of Marine Sciences (CCMAR), Portuguese Institute for Sea and Atmosphere(IPMA)"; Int32 institution_edmo_code 2516; String institution_edmo_uri "https://edmo.seadatanet.org/report/2516"; String keywords "acceptable, acoustic, acoustics, adcp, bad, beam, beams, bin, BINNUMBR, bottom, bottom-up, cells, circulation, CMAG01, CMAG02, CMAG03, CMAG04, component, correlation, correlation_magnitude, current, currents, data, depth, depth_cells, direction, doppler, earth, Earth Science > Oceans > Ocean Acoustics > Acoustic Velocity, Earth Science > Oceans > Ocean Circulation > Ocean Currents, Earth Science > Oceans > Ocean Temperature > Water Temperature, east, eastward, eastward_sea_water_velocity, echo, error, ewct, EWCT_QC, facing, flag, good, hcdt, HCDT_QC, hcsp, HCSP_QC, HDNG, heading, horizontal, horizontal velocity of the water column \\\\\\\\n(currents), indicative, indicative_error_from_multibeam_acoustic_doppler_velocity_profiler_in_sea_water, instrument, intensity, khz, latitude, LERR, longitude, magnitude, more, multibeam, north, northward, northward_sea_water_velocity, nsct, NSCT_QC, number, ocean, oceans, orientation, PCDG_3_beam_solution, PCGD_4_beam_solution, PCGD_bad, PCGD_Rej, percent, percentage, pitch, platform, platform_orientation, platform_pitch, platform_roll, POSITION_QC, profiler, proportion, proportion_of_acceptable_signal_returns_from_acoustic_instrument_in_sea_water, PTCH, quality, rejections, relative, returns, roll, science, sea, sea_water_speed, sea_water_temperature, sea_water_velocity_to_direction, seadatanet, seawater, sensor, sentinel, signal, signal_intensity_from_multibeam_acoustic_doppler_velocity_sensor_in_sea_water, solution, sound, sound velocity and travel time in the water column, south, south-north, speed, speed_of_sound_in_sea_water, statistics, subsurface, SVEL, TEMP, TEMP_QC, temperature, temperature of the water column, than, time, TNIH01, TNIH02, TNIH03, TNIH04, true, two, upward, upward_sea_water_velocity, v100, velocity, vertical velocity of the water column (currents), vsp, VSP_QC, water, west, west-east"; String keywords_vocabulary "GCMD Science Keywords"; String license "CC-BY-4.0"; String license_uri "https://spdx.org/licenses/CC-BY-4.0"; String network "EMSO-ERIC"; Float64 Northernmost_Northing 36.84848; String principal_investigator "Paulo Relvas"; String principal_investigator_email "prelvas@ualg.pt"; String project "EMSO-PT"; String site_code "IbMa-CSV"; String source "Subsurface upward facing ADCP"; String sourceUrl "(local files)"; Float64 Southernmost_Northing 36.84848; String standard_name_vocabulary "CF Standard Name Table v70"; String subsetVariables "latitude, longitude, POSITION_QC, TEMP_QC"; String summary "This dataset contains data collected with a Teledyne RDI Sentinel V100 300 kHz Acoustic Doppler Current Profiler (ADCP), mounted in a upward facing subsurface buoy. Data are collected every hour for 3.0m depth bins. Blank 2.0m"; String time_coverage_end "2022-10-06T11:00:00Z"; String time_coverage_start "2022-05-31T19:00:00Z"; String title "Sentinel ADCP Data at 150m Jun-Oct 2022 in front of Cape St.Vincent, Sagres, PT"; String update_interval "void"; Float64 Westernmost_Easting -8.927072; } }