ERDDAP
Easier access to scientific data |
|
Brought to you by NOAA NMFS SWFSC ERD |
| Dataset Title: | E2M3A timeSeries, data collected from 2021 to 2022
|
| Institution: | National Institute of Oceanography and Applied Geophysics - OGS, Division of Oceanography (Dataset ID: E2M3A_2021_2022_TS) |
| Information: | Summary
| License
| FGDC
| ISO 19115
| Metadata
| Background
| Make a graph
|
Attributes {
s {
time {
String _CoordinateAxisType "Time";
Float64 actual_range 1.6094592e+9, 1.669485745e+9;
String axis "T";
String cf_role "timeseries_id";
String ioos_category "Time";
String long_name "Time";
String sdn_parameter_name "Elapsed time relative to 1970-01-01T00:00:00Z";
String sdn_parameter_urn "SDN:P01::ELTMEP01";
String sdn_uom_name "Seconds";
String sdn_uom_urn "SDN:P06::UTBB";
String standard_name "time";
String time_origin "01-JAN-1970 00:00:00";
String units "seconds since 1970-01-01T00:00:00Z";
}
latitude {
String _CoordinateAxisType "Lat";
Float64 actual_range 41.5277, 41.5277;
String axis "Y";
String ioos_category "Location";
String long_name "Latitude";
String sdn_parameter_name "Latitude north";
String sdn_parameter_urn "SDN:P01::ALATZZ01";
String sdn_uom_name "Degrees north";
String sdn_uom_urn "SDN:P06::DEGN";
String standard_name "latitude";
String units "degrees_north";
}
longitude {
String _CoordinateAxisType "Lon";
Float64 actual_range 18.0824167, 18.0824167;
String axis "X";
String ioos_category "Location";
String long_name "Longitude";
String sdn_parameter_name "Longitude east";
String sdn_parameter_urn "SDN:P01::ALONZZ01";
String sdn_uom_name "Degrees east";
String sdn_uom_urn "SDN:P06::DEGE";
String standard_name "longitude";
String units "degrees_east";
}
depth {
String _CoordinateAxisType "Height";
String _CoordinateZisPositive "down";
Float32 actual_range -5.0, 5.0;
String axis "Z";
String ioos_category "Location";
String long_name "Depth";
String positive "down";
String reference "sea_level";
String sdn_parameter_name "Depth (spatial coordinate) relative to water surface in the water body";
String sdn_parameter_urn "SDN:P01::ADEPZZ01";
String sdn_uom_name "Metres";
String sdn_uom_urn "SDN:P06::ULAA";
String standard_name "depth";
String units "m";
}
WDIR {
Float32 _FillValue -999.0;
Float32 actual_range 0.0, 360.0;
String ancillary_variables "WDIR_QC";
String coordinates "TIME; DEPTH; LATITUDE; LONGITUDE";
String data_mode "R";
String ioos_category "Wind";
String long_name "Wind from direction relative true north";
String sdn_parameter_name "Direction (from) of wind relative to True North {wind direction} in the atmosphere";
String sdn_parameter_urn "SDN:P01::EWDAZZ01";
String sdn_uom_name "Degrees";
String sdn_uom_urn "SDN:P06::UAAA";
String sensor_manufacturer "R.M. Young";
String sensor_manufacturer_uri "https://vocab.nerc.ac.uk/collection/L35/current/MAN0037/";
String sensor_manufacturer_urn "SDN:L35::MAN0037";
String sensor_model "RM Young 04106 Wind Monitor JR (marine) anemometer";
String sensor_mount "mounted_on_surface_buoy";
String sensor_orientation "horizontal";
String sensor_reference "https://vocab.nerc.ac.uk/collection/L22/current/TOOL1428/";
String sensor_SeaVoX_L22_code "SDN:L22::TOOL1428";
String sensor_serial_number "SN-OGS-10034";
String standard_name "wind_from_direction";
String units "Degrees";
}
WDIR_QC {
Byte _FillValue -127;
String _Unsigned "false";
Byte actual_range 1, 9;
Byte colorBarMaximum 9;
Byte colorBarMinimum 0;
String conventions "Copernicus Marine In Situ reference table 2";
String flag_meanings "no_qc_performed good_data probably_good_data bad_data_that_are_potentially_correctable bad_data value_changed value_below_detection nominal_value interpolated_value missing_value";
Byte flag_values 0, 1, 2, 3, 4, 5, 6, 7, 8, 9;
String ioos_category "Quality";
String long_name "Wind from direction relative true north quality flag";
String standard_name "quality_flag";
Byte valid_max 9;
Byte valid_min 0;
}
WSPD {
Float32 _FillValue -999.0;
Float32 actual_range 0.0, 15.6;
String ancillary_variables "WSPD_QC";
String coordinates "TIME; DEPTH; LATITUDE; LONGITUDE";
String data_mode "R";
String ioos_category "Wind";
String long_name "Horizontal wind speed";
String sdn_parameter_name "Speed of wind {wind speed} in the atmosphere";
String sdn_parameter_urn "SDN:P01::EWSBZZ01";
String sdn_uom_name "Metres per second";
String sdn_uom_urn "SDN:P06::UVAA";
String sensor_manufacturer "R.M. Young";
String sensor_manufacturer_uri "https://vocab.nerc.ac.uk/collection/L35/current/MAN0037/";
String sensor_manufacturer_urn "SDN:L35::MAN0037";
String sensor_model "RM Young 04106 Wind Monitor JR (marine) anemometer";
String sensor_mount "mounted_on_surface_buoy";
String sensor_orientation "horizontal";
String sensor_reference "https://vocab.nerc.ac.uk/collection/L22/current/TOOL1428/";
String sensor_SeaVoX_L22_code "SDN:L22::TOOL1428";
String sensor_serial_number "SN-OGS-10034";
String standard_name "wind_speed";
String units "Metres per second";
}
WSPD_QC {
Byte _FillValue -127;
String _Unsigned "false";
Byte actual_range 1, 9;
Byte colorBarMaximum 9;
Byte colorBarMinimum 0;
String conventions "Copernicus Marine In Situ reference table 2";
String flag_meanings "no_qc_performed good_data probably_good_data bad_data_that_are_potentially_correctable bad_data value_changed value_below_detection nominal_value interpolated_value missing_value";
Byte flag_values 0, 1, 2, 3, 4, 5, 6, 7, 8, 9;
String ioos_category "Quality";
String long_name "Horizontal wind speed quality flag";
String standard_name "quality_flag";
Byte valid_max 9;
Byte valid_min 0;
}
DRYT {
Float32 _FillValue -999.0;
Float32 actual_range -46.98, 38.36;
String ancillary_variables "DRYT_QC";
String coordinates "TIME; DEPTH; LATITUDE; LONGITUDE";
String data_mode "R";
String ioos_category "Temperature";
String long_name "Air temperature in dry bulb";
String sdn_parameter_name "Temperature of the atmosphere";
String sdn_parameter_urn "SDN:P01::CTMPZZ01";
String sdn_uom_name "Degrees Celsius";
String sdn_uom_urn "SDN:P06::UPAA";
String sensor_manufacturer "R.M. Young";
String sensor_manufacturer_uri "https://vocab.nerc.ac.uk/collection/L35/current/MAN0037/";
String sensor_manufacturer_urn "SDN:L35::MAN0037";
String sensor_model "RM Young 41372 hygrometer";
String sensor_mount "mounted_on_surface_buoy";
String sensor_orientation "horizontal";
String sensor_reference "https://vocab.nerc.ac.uk/collection/L22/current/TOOL1517/";
String sensor_SeaVoX_L22_code "SDN:L22::TOOL1517";
String sensor_serial_number "SN-OGS-10037";
String standard_name "air_temperature";
String units "Degrees Celsius";
}
DRYT_QC {
Byte _FillValue -127;
String _Unsigned "false";
Byte actual_range 1, 9;
Byte colorBarMaximum 9;
Byte colorBarMinimum 0;
String conventions "Copernicus Marine In Situ reference table 2";
String flag_meanings "no_qc_performed good_data probably_good_data bad_data_that_are_potentially_correctable bad_data value_changed value_below_detection nominal_value interpolated_value missing_value";
Byte flag_values 0, 1, 2, 3, 4, 5, 6, 7, 8, 9;
String ioos_category "Quality";
String long_name "Air temperature in dry bulb quality flag";
String standard_name "quality_flag";
Byte valid_max 9;
Byte valid_min 0;
}
ATMS {
Float32 _FillValue -999.0;
Float32 actual_range 0.0, 1041.44;
String ancillary_variables "ATMS_QC";
String coordinates "TIME; DEPTH; LATITUDE; LONGITUDE";
String data_mode "R";
String ioos_category "Meteorology";
String long_name "Atmospheric pressure at sea level";
String sdn_parameter_name "Pressure (measured variable) exerted by the atmosphere by unknown instrument and correction to sea level";
String sdn_parameter_urn "SDN:P01::CAPAZZ01";
String sdn_uom_name "Millibars";
String sdn_uom_urn "SDN:P06::UPBB";
String sensor_manufacturer "R.M. Young";
String sensor_manufacturer_uri "https://vocab.nerc.ac.uk/collection/L35/current/MAN0037/";
String sensor_manufacturer_urn "SDN:L35::MAN0037";
String sensor_model "Young 61302 barometric pressure sensor";
String sensor_mount "mounted_on_surface_buoy";
String sensor_orientation "horizontal";
String sensor_reference "https://vocab.nerc.ac.uk/collection/L22/current/TOOL1001/";
String sensor_SeaVoX_L22_code "SDN:L22::TOOL1001";
String sensor_serial_number "SN-OGS-10035";
String standard_name "air_pressure_at_sea_level";
String units "Millibars";
}
ATMS_QC {
Byte _FillValue -127;
String _Unsigned "false";
Byte actual_range 1, 9;
Byte colorBarMaximum 9;
Byte colorBarMinimum 0;
String conventions "Copernicus Marine In Situ reference table 2";
String flag_meanings "no_qc_performed good_data probably_good_data bad_data_that_are_potentially_correctable bad_data value_changed value_below_detection nominal_value interpolated_value missing_value";
Byte flag_values 0, 1, 2, 3, 4, 5, 6, 7, 8, 9;
String ioos_category "Quality";
String long_name "Atmospheric pressure at sea level quality flag";
String standard_name "quality_flag";
Byte valid_max 9;
Byte valid_min 0;
}
RELH {
Float32 _FillValue -999.0;
Float32 actual_range 0.0, 344.3;
String ancillary_variables "RELH_QC";
String coordinates "TIME; DEPTH; LATITUDE; LONGITUDE";
String data_mode "R";
String ioos_category "Meteorology";
String long_name "Relative humidity";
String sdn_parameter_name "Relative humidity of the atmosphere";
String sdn_parameter_urn "SDN:P01::CRELZZ01";
String sdn_uom_name "Percent";
String sdn_uom_urn "SDN:P06::UPCT";
String sensor_manufacturer "R.M. Young";
String sensor_manufacturer_uri "https://vocab.nerc.ac.uk/collection/L35/current/MAN0037/";
String sensor_manufacturer_urn "SDN:L35::MAN0037";
String sensor_model "RM Young 41372 hygrometer";
String sensor_mount "mounted_on_surface_buoy";
String sensor_orientation "horizontal";
String sensor_reference "https://vocab.nerc.ac.uk/collection/L22/current/TOOL1517/";
String sensor_SeaVoX_L22_code "SDN:L22::TOOL1517";
String sensor_serial_number "SN-OGS-10037";
String standard_name "relative_humidity";
String units "Percent";
}
RELH_QC {
Byte _FillValue -127;
String _Unsigned "false";
Byte actual_range 1, 9;
Byte colorBarMaximum 9;
Byte colorBarMinimum 0;
String conventions "Copernicus Marine In Situ reference table 2";
String flag_meanings "no_qc_performed good_data probably_good_data bad_data_that_are_potentially_correctable bad_data value_changed value_below_detection nominal_value interpolated_value missing_value";
Byte flag_values 0, 1, 2, 3, 4, 5, 6, 7, 8, 9;
String ioos_category "Quality";
String long_name "Relative humidity quality flag";
String standard_name "quality_flag";
Byte valid_max 9;
Byte valid_min 0;
}
GSPD {
Float32 _FillValue -999.0;
Float32 actual_range 0.0, 272.3;
String ancillary_variables "GSPD_QC";
String coordinates "TIME; DEPTH; LATITUDE; LONGITUDE";
String data_mode "R";
String ioos_category "Wind";
String long_name "Gust wind speed";
String sdn_parameter_name "Speed of wind (gust) {wind speed} in the atmosphere";
String sdn_parameter_urn "SDN:P01::EGTSZZ01";
String sdn_uom_name "Metres per second";
String sdn_uom_urn "SDN:P06::UVAA";
String sensor_manufacturer "R.M. Young";
String sensor_manufacturer_uri "https://vocab.nerc.ac.uk/collection/L35/current/MAN0037/";
String sensor_manufacturer_urn "SDN:L35::MAN0037";
String sensor_model "RM Young 04106 Wind Monitor JR (marine) anemometer";
String sensor_mount "mounted_on_surface_buoy";
String sensor_orientation "horizontal";
String sensor_reference "https://vocab.nerc.ac.uk/collection/L22/current/TOOL1428/";
String sensor_SeaVoX_L22_code "SDN:L22::TOOL1428";
String sensor_serial_number "SN-OGS-10034";
String standard_name "wind_speed_of_gust";
String units "Metres per second";
}
GSPD_QC {
Byte _FillValue -127;
String _Unsigned "false";
Byte actual_range 1, 9;
Byte colorBarMaximum 9;
Byte colorBarMinimum 0;
String conventions "Copernicus Marine In Situ reference table 2";
String flag_meanings "no_qc_performed good_data probably_good_data bad_data_that_are_potentially_correctable bad_data value_changed value_below_detection nominal_value interpolated_value missing_value";
Byte flag_values 0, 1, 2, 3, 4, 5, 6, 7, 8, 9;
String ioos_category "Quality";
String long_name "Gust wind speed quality flag";
String standard_name "quality_flag";
Byte valid_max 9;
Byte valid_min 0;
}
GDIR {
Float32 _FillValue -999.0;
Float32 actual_range 0.0, 359.9;
String ancillary_variables "GDIR_QC";
String coordinates "TIME; DEPTH; LATITUDE; LONGITUDE";
String data_mode "R";
String ioos_category "Wind";
String long_name "Gust wind from direction relative true north";
String sdn_parameter_name "Direction (from) of wind (gust) relative to True North {wind direction} in the atmosphere";
String sdn_parameter_urn "SDN:P01::EGTDZZ01";
String sdn_uom_name "Degrees";
String sdn_uom_urn "SDN:P06::UAAA";
String sensor_manufacturer "R.M. Young";
String sensor_manufacturer_uri "https://vocab.nerc.ac.uk/collection/L35/current/MAN0037/";
String sensor_manufacturer_urn "SDN:L35::MAN0037";
String sensor_model "RM Young 04106 Wind Monitor JR (marine) anemometer";
String sensor_mount "mounted_on_surface_buoy";
String sensor_orientation "horizontal";
String sensor_reference "https://vocab.nerc.ac.uk/collection/L22/current/TOOL1428/";
String sensor_SeaVoX_L22_code "SDN:L22::TOOL1428";
String sensor_serial_number "SN-OGS-10034";
String standard_name "wind_gust_from_direction";
String units "Degrees";
}
GDIR_QC {
Byte _FillValue -127;
String _Unsigned "false";
Byte actual_range 1, 9;
Byte colorBarMaximum 9;
Byte colorBarMinimum 0;
String conventions "Copernicus Marine In Situ reference table 2";
String flag_meanings "no_qc_performed good_data probably_good_data bad_data_that_are_potentially_correctable bad_data value_changed value_below_detection nominal_value interpolated_value missing_value";
Byte flag_values 0, 1, 2, 3, 4, 5, 6, 7, 8, 9;
String ioos_category "Quality";
String long_name "Gust wind from direction relative true north quality flag";
String standard_name "quality_flag";
Byte valid_max 9;
Byte valid_min 0;
}
PHPH {
Float32 _FillValue -999.0;
Float32 actual_range 4.8941, 8.5609;
String ancillary_variables "PHPH_QC";
String coordinates "TIME; DEPTH; LATITUDE; LONGITUDE";
String data_mode "R";
String ioos_category "Other";
String long_name "Ph";
String sdn_parameter_name "pH (unspecified scale) of the water body";
String sdn_parameter_urn "SDN:P01::PHXXZZXX";
String sdn_uom_name "pH units";
String sdn_uom_urn "SDN:P06::UUPH";
String sensor_manufacturer "Sunburst Sensors";
String sensor_manufacturer_uri "https://vocab.nerc.ac.uk/collection/L35/current/MAN0097/";
String sensor_manufacturer_urn "SDN:L35::MAN0097";
String sensor_model "Sunburst Sensors Submersible Autonomous Moored Instrument pH {SAMI-pH} seawater and freshwater pH sensor series";
String sensor_mount "mounted_on_surface_buoy_tether";
String sensor_orientation "horizontal";
String sensor_reference "https://vocab.nerc.ac.uk/collection/L22/current/TOOL1613/";
String sensor_SeaVoX_L22_code "SDN:L22::TOOL1613";
String sensor_serial_number "P-0007";
String standard_name "sea_water_ph_reported_on_total_scale";
String units "pH units";
}
PHPH_QC {
Byte _FillValue -127;
String _Unsigned "false";
Byte actual_range 1, 9;
Byte colorBarMaximum 9;
Byte colorBarMinimum 0;
String conventions "Copernicus Marine In Situ reference table 2";
String flag_meanings "no_qc_performed good_data probably_good_data bad_data_that_are_potentially_correctable bad_data value_changed value_below_detection nominal_value interpolated_value missing_value";
Byte flag_values 0, 1, 2, 3, 4, 5, 6, 7, 8, 9;
String ioos_category "Quality";
String long_name "Ph quality flag";
String standard_name "quality_flag";
Byte valid_max 9;
Byte valid_min 0;
}
DOX1 {
Float64 _FillValue -999.0;
Float64 actual_range 4.091, 6.762;
String ancillary_variables "DOX1_QC";
String coordinates "TIME; DEPTH; LATITUDE; LONGITUDE";
String data_mode "R";
String ioos_category "Dissolved O2";
String long_name "Dissolved oxygen";
String sdn_parameter_name "Concentration of oxygen {O2 CAS 7782-44-7} per unit volume of the water body [dissolved plus reactive particulate phase]";
String sdn_parameter_urn "SDN:P01::DOXYZZXX";
String sdn_uom_name "Millilitres per litre";
String sdn_uom_urn "SDN:P06::UMLL";
String sensor_manufacturer "Sea-Bird Scientific";
String sensor_manufacturer_uri "https://vocab.nerc.ac.uk/collection/L35/current/MAN0013/";
String sensor_manufacturer_urn "SDN:L35::MAN0013";
String sensor_model "Sea-Bird SBE 37 MicroCat SMP-CT-ODO with optional pressure (submersible) CTD sensor series";
String sensor_mount "mounted_on_surface_buoy_tether";
String sensor_orientation "horizontal";
String sensor_reference "https://vocab.nerc.ac.uk/collection/L22/current/TOOL0869/";
String sensor_SeaVoX_L22_code "SDN:L22::TOOL0869";
String sensor_serial_number "10597";
String standard_name "volume_fraction_of_oxygen_in_sea_water";
String units "Millilitres per litre";
}
DOX1_QC {
Byte _FillValue -127;
String _Unsigned "false";
Byte actual_range 1, 1;
Byte colorBarMaximum 9;
Byte colorBarMinimum 0;
String conventions "Copernicus Marine In Situ reference table 2";
String flag_meanings "no_qc_performed good_data probably_good_data bad_data_that_are_potentially_correctable bad_data value_changed value_below_detection nominal_value interpolated_value missing_value";
Byte flag_values 0, 1, 2, 3, 4, 5, 6, 7, 8, 9;
String ioos_category "Quality";
String long_name "Dissolved oxygen quality flag";
String standard_name "quality_flag";
Byte valid_max 9;
Byte valid_min 0;
}
TEMP {
Float32 _FillValue -999.0;
Float32 actual_range 13.9769, 46.4401;
String ancillary_variables "TEMP_QC";
String coordinates "TIME; DEPTH; LATITUDE; LONGITUDE";
String data_mode "R";
String ioos_category "Temperature";
String long_name "Sea temperature";
String sdn_parameter_name "Temperature of the water body";
String sdn_parameter_urn "SDN:P01::TEMPPR01";
String sdn_uom_name "Degrees Celsius";
String sdn_uom_urn "SDN:P06::UPAA";
String sensor_manufacturer "Sea-Bird Scientific";
String sensor_manufacturer_uri "https://vocab.nerc.ac.uk/collection/L35/current/MAN0013/";
String sensor_manufacturer_urn "SDN:L35::MAN0013";
String sensor_model "Sea-Bird SBE 37 MicroCat SMP-CT-ODO with optional pressure (submersible) CTD sensor series";
String sensor_mount "mounted_on_surface_buoy_tether";
String sensor_orientation "horizontal";
String sensor_reference "https://vocab.nerc.ac.uk/collection/L22/current/TOOL0869/";
String sensor_SeaVoX_L22_code "SDN:L22::TOOL0869";
String sensor_serial_number "10597";
String standard_name "sea_water_temperature";
String units "Degrees Celsius";
}
TEMP_QC {
Byte _FillValue -127;
String _Unsigned "false";
Byte actual_range 1, 4;
Byte colorBarMaximum 9;
Byte colorBarMinimum 0;
String conventions "Copernicus Marine In Situ reference table 2";
String flag_meanings "no_qc_performed good_data probably_good_data bad_data_that_are_potentially_correctable bad_data value_changed value_below_detection nominal_value interpolated_value missing_value";
Byte flag_values 0, 1, 2, 3, 4, 5, 6, 7, 8, 9;
String ioos_category "Quality";
String long_name "Sea temperature quality flag";
String standard_name "quality_flag";
Byte valid_max 9;
Byte valid_min 0;
}
CNDC {
Float32 _FillValue -999.0;
Float32 actual_range -0.0016, 9822.0;
String ancillary_variables "CNDC_QC";
String coordinates "TIME; DEPTH; LATITUDE; LONGITUDE";
String data_mode "R";
String ioos_category "Salinity";
String long_name "Electrical conductivity";
String sdn_parameter_name "Electrical conductivity of the water body";
String sdn_parameter_urn "SDN:P01::CNDCZZ01";
String sdn_uom_name "Siemens per metre";
String sdn_uom_urn "SDN:P06::UECA";
String sensor_manufacturer "Sea-Bird Scientific";
String sensor_manufacturer_uri "https://vocab.nerc.ac.uk/collection/L35/current/MAN0013/";
String sensor_manufacturer_urn "SDN:L35::MAN0013";
String sensor_model "Sea-Bird SBE 37 MicroCat SMP-CT-ODO with optional pressure (submersible) CTD sensor series";
String sensor_mount "mounted_on_surface_buoy_tether";
String sensor_orientation "horizontal";
String sensor_reference "https://vocab.nerc.ac.uk/collection/L22/current/TOOL0869/";
String sensor_SeaVoX_L22_code "SDN:L22::TOOL0869";
String sensor_serial_number "10597";
String standard_name "sea_water_electrical_conductivity";
String units "Siemens per metre";
}
CNDC_QC {
Byte _FillValue -127;
String _Unsigned "false";
Byte actual_range 1, 4;
Byte colorBarMaximum 9;
Byte colorBarMinimum 0;
String conventions "Copernicus Marine In Situ reference table 2";
String flag_meanings "no_qc_performed good_data probably_good_data bad_data_that_are_potentially_correctable bad_data value_changed value_below_detection nominal_value interpolated_value missing_value";
Byte flag_values 0, 1, 2, 3, 4, 5, 6, 7, 8, 9;
String ioos_category "Quality";
String long_name "Electrical conductivity quality flag";
String standard_name "quality_flag";
Byte valid_max 9;
Byte valid_min 0;
}
PSAL {
Float32 _FillValue -999.0;
Float32 actual_range -0.193, 6.292;
String ancillary_variables "PSAL_QC";
String coordinates "TIME; DEPTH; LATITUDE; LONGITUDE";
String data_mode "R";
String ioos_category "Salinity";
String long_name "Practical salinity";
String sdn_parameter_name "Practical salinity of the water body";
String sdn_parameter_urn "SDN:P01::PSLTZZ01";
String sdn_uom_name "Dimensionless";
String sdn_uom_urn "SDN:P06::UUUU";
String sensor_manufacturer "Sea-Bird Scientific";
String sensor_manufacturer_uri "https://vocab.nerc.ac.uk/collection/L35/current/MAN0013/";
String sensor_manufacturer_urn "SDN:L35::MAN0013";
String sensor_model "Sea-Bird SBE 37 MicroCat SMP-CT-ODO with optional pressure (submersible) CTD sensor series";
String sensor_mount "mounted_on_surface_buoy_tether";
String sensor_orientation "horizontal";
String sensor_reference "https://vocab.nerc.ac.uk/collection/L22/current/TOOL0869/";
String sensor_SeaVoX_L22_code "SDN:L22::TOOL0869";
String sensor_serial_number "10597";
String standard_name "sea_water_practical_salinity";
String units "1";
}
PSAL_QC {
Byte _FillValue -127;
String _Unsigned "false";
Byte actual_range 1, 4;
Byte colorBarMaximum 9;
Byte colorBarMinimum 0;
String conventions "Copernicus Marine In Situ reference table 2";
String flag_meanings "no_qc_performed good_data probably_good_data bad_data_that_are_potentially_correctable bad_data value_changed value_below_detection nominal_value interpolated_value missing_value";
Byte flag_values 0, 1, 2, 3, 4, 5, 6, 7, 8, 9;
String ioos_category "Quality";
String long_name "Practical salinity quality flag";
String standard_name "quality_flag";
Byte valid_max 9;
Byte valid_min 0;
}
PRES {
Float32 _FillValue -999.0;
Float32 actual_range 0.0084, 39.2054;
String ancillary_variables "PRES_QC";
String coordinates "TIME; DEPTH; LATITUDE; LONGITUDE";
String data_mode "R";
String ioos_category "Pressure";
String long_name "Sea pressure";
String sdn_parameter_name "Pressure (spatial coordinate) exerted by the water body by profiling pressure sensor and correction to read zero at sea level";
String sdn_parameter_urn "SDN:P01::PRESPR01";
String sdn_uom_name "Decibars";
String sdn_uom_urn "SDN:P06::UPDB";
String sensor_manufacturer "Sea-Bird Scientific";
String sensor_manufacturer_uri "https://vocab.nerc.ac.uk/collection/L35/current/MAN0013/";
String sensor_manufacturer_urn "SDN:L35::MAN0013";
String sensor_model "Sea-Bird SBE 37 MicroCat SMP-CT-ODO with optional pressure (submersible) CTD sensor series";
String sensor_mount "mounted_on_surface_buoy_tether";
String sensor_orientation "horizontal";
String sensor_reference "https://vocab.nerc.ac.uk/collection/L22/current/TOOL0869/";
String sensor_SeaVoX_L22_code "SDN:L22::TOOL0869";
String sensor_serial_number "10597";
String standard_name "sea_water_pressure";
String units "Decibars";
}
PRES_QC {
Byte _FillValue -127;
String _Unsigned "false";
Byte actual_range 0, 2;
Byte colorBarMaximum 9;
Byte colorBarMinimum 0;
String conventions "Copernicus Marine In Situ reference table 2";
String flag_meanings "no_qc_performed good_data probably_good_data bad_data_that_are_potentially_correctable bad_data value_changed value_below_detection nominal_value interpolated_value missing_value";
Byte flag_values 0, 1, 2, 3, 4, 5, 6, 7, 8, 9;
String ioos_category "Quality";
String long_name "Sea pressure quality flag";
String standard_name "quality_flag";
Byte valid_max 9;
Byte valid_min 0;
}
PCO2 {
Float32 _FillValue -999.0;
Float32 actual_range 0.0, 23807.68;
String ancillary_variables "PCO2_QC";
String coordinates "TIME; DEPTH; LATITUDE; LONGITUDE";
String data_mode "R";
String ioos_category "CO2";
String long_name "CO2 partial pressure";
String sdn_parameter_name "Partial pressure of carbon dioxide {CO2 CAS 124-38-9} {pCO2} in the water body by equilibration with air, drying and infra-red gas analysis";
String sdn_parameter_urn "SDN:P01::PCO2EG01";
String sdn_uom_name "Microatmospheres";
String sdn_uom_urn "SDN:P06::UATM";
String sensor_manufacturer "Pro Oceanus";
String sensor_manufacturer_uri "https://vocab.nerc.ac.uk/collection/L35/current/MAN0033/";
String sensor_manufacturer_urn "SDN:L35::MAN0033";
String sensor_model "Pro Oceanus CO2-Pro Submersible pCO2 Sensor";
String sensor_mount "mounted_on_surface_buoy_tether";
String sensor_orientation "horizontal";
String sensor_reference "https://vocab.nerc.ac.uk/collection/L22/current/TOOL1119/";
String sensor_SeaVoX_L22_code "SDN:L22::TOOL1119";
String sensor_serial_number "29-103-4";
String standard_name "surface_partial_pressure_of_carbon_dioxide_in_sea_water";
String units "Microatmospheres";
}
PCO2_QC {
Byte _FillValue -127;
String _Unsigned "false";
Byte actual_range 1, 9;
Byte colorBarMaximum 9;
Byte colorBarMinimum 0;
String conventions "Copernicus Marine In Situ reference table 2";
String flag_meanings "no_qc_performed good_data probably_good_data bad_data_that_are_potentially_correctable bad_data value_changed value_below_detection nominal_value interpolated_value missing_value";
Byte flag_values 0, 1, 2, 3, 4, 5, 6, 7, 8, 9;
String ioos_category "Quality";
String long_name "CO2 partial pressure quality flag";
String standard_name "quality_flag";
Byte valid_max 9;
Byte valid_min 0;
}
SINC {
Float32 _FillValue -999.0;
Float32 actual_range -12.9, 1198.7;
String ancillary_variables "SINC_QC";
String coordinates "TIME; DEPTH; LATITUDE; LONGITUDE";
String data_mode "R";
String ioos_category "Heat Flux";
String long_name "Shortwave/solar incoming radiation";
String sdn_parameter_name "Downwelling vector irradiance as energy of electromagnetic radiation (solar wavelengths) in the atmosphere by pyranometer";
String sdn_parameter_urn "SDN:P01::CSLRZZ01";
String sdn_uom_name "Watts per square metre";
String sdn_uom_urn "SDN:P06::UFAA";
String sensor_manufacturer "Unknown";
String sensor_manufacturer_uri "https://vocab.nerc.ac.uk/collection/L35/current/MAN0002/";
String sensor_manufacturer_urn "SDN:L35::MAN0002";
String sensor_model "Eppley Precision Spectral Pyranometer";
String sensor_mount "mounted_on_surface_buoy";
String sensor_orientation "horizontal";
String sensor_reference "https://vocab.nerc.ac.uk/collection/L22/current/TOOL0666/";
String sensor_SeaVoX_L22_code "SDN:L22::TOOL0666";
String sensor_serial_number "35547F3";
String standard_name "surface_downwelling_shortwave_flux_in_air";
String units "Watts per square metre";
}
SINC_QC {
Byte _FillValue -127;
String _Unsigned "false";
Byte actual_range 0, 9;
Byte colorBarMaximum 9;
Byte colorBarMinimum 0;
String conventions "Copernicus Marine In Situ reference table 2";
String flag_meanings "no_qc_performed good_data probably_good_data bad_data_that_are_potentially_correctable bad_data value_changed value_below_detection nominal_value interpolated_value missing_value";
Byte flag_values 0, 1, 2, 3, 4, 5, 6, 7, 8, 9;
String ioos_category "Quality";
String long_name "Shortwave/solar incoming radiation quality flag";
String standard_name "quality_flag";
Byte valid_max 9;
Byte valid_min 0;
}
LINC {
Float32 _FillValue -999.0;
Float32 actual_range -273.1, 41.7;
String ancillary_variables "LINC_QC";
String coordinates "TIME; DEPTH; LATITUDE; LONGITUDE";
String data_mode "R";
String ioos_category "Heat Flux";
String long_name "Longwave/atmospheric incoming radiation";
String sdn_parameter_name "Downwelling vector irradiance as energy of electromagnetic radiation (longwave) in the atmosphere";
String sdn_parameter_urn "SDN:P01::LWRDZZ01";
String sdn_uom_name "Watts per square metre";
String sdn_uom_urn "SDN:P06::UFAA";
String sensor_manufacturer "Unknown";
String sensor_manufacturer_uri "https://vocab.nerc.ac.uk/collection/L35/current/MAN0002/";
String sensor_manufacturer_urn "SDN:L35::MAN0002";
String sensor_model "Eppley Precision Infrared Radiometer Pyrgeometer";
String sensor_mount "mounted_on_surface_buoy";
String sensor_orientation "horizontal";
String sensor_reference "https://vocab.nerc.ac.uk/collection/L22/current/TOOL0083/";
String sensor_SeaVoX_L22_code "SDN:L22::TOOL0083";
String sensor_serial_number "37630F3";
String standard_name "surface_downwelling_longwave_flux_in_air";
String units "Watts per square metre";
}
LINC_QC {
Byte _FillValue -127;
String _Unsigned "false";
Byte actual_range 0, 9;
Byte colorBarMaximum 9;
Byte colorBarMinimum 0;
String conventions "Copernicus Marine In Situ reference table 2";
String flag_meanings "no_qc_performed good_data probably_good_data bad_data_that_are_potentially_correctable bad_data value_changed value_below_detection nominal_value interpolated_value missing_value";
Byte flag_values 0, 1, 2, 3, 4, 5, 6, 7, 8, 9;
String ioos_category "Quality";
String long_name "Longwave/atmospheric incoming radiation quality flag";
String standard_name "quality_flag";
Byte valid_max 9;
Byte valid_min 0;
}
}
NC_GLOBAL {
String cdm_data_type "TimeSeries";
String cdm_timeseries_variables "time,depth,latitude,longitude";
String Conventions "CF-1.6, Copernicus-InSituTAC-FormatManual-1.42, Copernicus-InSituTAC-SRD-1.5, Copernicus-InSituTAC-ParametersList-3.2.0, COARDS, ACDD-1.3, OceanSITES v1.4, SeaDataNet_1.0, NCCSV-1.1";
String creator_email "nodc@ogs.it";
String creator_type "institution";
String creator_url "https://nodc.ogs.it";
String data_mode "R";
String data_type "OceanSITES time-series data";
String date_created "2021-01-01T00:00:00Z";
Float64 Easternmost_Easting 18.0824167;
String emso_facility "South Adriatic Sea";
String featureType "TimeSeries";
String format_version "1.4";
Float64 geospatial_lat_max 41.5277;
Float64 geospatial_lat_min 41.5277;
String geospatial_lat_units "degrees_north";
Float64 geospatial_lon_max 18.0824167;
Float64 geospatial_lon_min 18.0824167;
String geospatial_lon_units "degrees_east";
Float64 geospatial_vertical_max 5.0;
Float64 geospatial_vertical_min -5.0;
String geospatial_vertical_positive "down";
String geospatial_vertical_units "m";
String history
"moored surface buoy
2025-10-29T22:50:59Z (source database)
2025-10-29T22:50:59Z https://erddap.emso.eu/erddap/tabledap/E2M3A_2021_2022_TS.html";
String id "E2M3A_TS";
String infoUrl "https://nodc.ogs.it";
String institution "National Institute of Oceanography and Applied Geophysics - OGS, Division of Oceanography";
String institution_edmo_code "120";
String institution_edmo_uri "https://edmo.seadatanet.org/report/120";
String keywords "AHGT, ALAT, ALKY, AYMD, CAPH, CDTA, CHUM, CNDC, CSLR, DOXY, EWSB, LWRD, PCO2, TEMP";
String keywords_vocabulary "SeaDataNet Parameter Discovery Vocabulary";
String license "CC-BY-4.0";
String license_uri "https://spdx.org/licenses/CC-BY-4.0";
String network "OceanSITES,EMSO-ERIC";
Float64 Northernmost_Northing 41.5277;
String platform_code "E2M3A";
String principal_investigator "Vanessa Rossana Cardin";
String principal_investigator_email "vcardin@ogs.it";
String site_code "E2M3A";
String source "moored surface buoy";
String source_platform_category_code "41";
String sourceUrl "(source database)";
Float64 Southernmost_Northing 41.5277;
String standard_name_vocabulary "CF Standard Name Table v70";
String summary "E2M3A timeSeries, data collected from 2021 to 2022";
String time_coverage_end "2022-11-26T18:02:25Z";
String time_coverage_start "2021-01-01T00:00:00Z";
String title "E2M3A timeSeries, data collected from 2021 to 2022";
String update_interval "void";
Float64 Westernmost_Easting 18.0824167;
String wmo_platform_code "6100278";
}
}
Data Access Protocol (DAP)
and its
selection constraints
.
The URL specifies what you want: the dataset, a description of the graph or the subset of the data, and the file type for the response.
Tabledap request URLs must be in the form
https://coastwatch.pfeg.noaa.gov/erddap/tabledap/datasetID.fileType{?query}
For example,
https://coastwatch.pfeg.noaa.gov/erddap/tabledap/pmelTaoDySst.htmlTable?longitude,latitude,time,station,wmo_platform_code,T_25&time>=2015-05-23T12:00:00Z&time<=2015-05-31T12:00:00Z
Thus, the query is often a comma-separated list of desired variable names,
followed by a collection of
constraints (e.g., variable<value),
each preceded by '&' (which is interpreted as "AND").
For details, see the tabledap Documentation.